NDT

NDT

Cathodic Protection - Buckleys

Buckleys
Calibration Kits

Calibration kit for UCP1A/UCP1B CP probes

The Calibration Kit has been created to provide all the necessary components to enable customers to verify the accuracy of the readings on the Buckleys Contact and Proximity Probes so that in-house verification can be carried out.

Providing the readings are correct, the silver/silver chloride screw-in half cell should be checked by using K-SAT Reference Cells in a standard salt water solution.

To confirm the readings, three cells should be used and the sea water corrosion test mixture should be made up to a 3% solution.

KIT COMPRISES

  • 3 x screw-on K-SAT Reference Electrode Cells
  • Sea water corrosion test mixture
  • 3 x Adaptor leads
  • 1 x zinc block
  • Full instructions for ‘in-house’ verification
FEATURES
  • Easy to use
  • All kit parts can be replaced individually
  • Full instructions included
CALIBRATION KIT FOR UCP1A/UCP1B PROBES
Electrical connectionscrew fit
Output+196mV @ 25°C vs SHE
Accuracy±10mV @ 25°C vs SHE
Temperature coeff-0.64mV per/°C
Temperature range0 - 40 °C
Working lifeup to 1 year
Dimensions155mm long x 25mm diam.
Packed weight (calibration kit)1.05Kg
Dimensions (packed)26cm x 14cm x 30cm
Note: Due to ongoing technical developments, all stated information is typical and is subject to change without notice or obligation.
DESCRIPTIONPART NUMBERS
Calibration kit for UCP1A/UCP1B CP probesBC-6004-0032