NDT

NDT

Cathodic Protection - Buckleys

Buckleys
Calibration Kits

BathyCorrometer® Calibration Kit

The Calibration Kit has been created to provide all the necessary components to enable customers to verify the accuracy of the readings on the Buckleys or Roxby BathyCorrometers® so that ‘in-house’ verification can be carried out.

The process requires two areas to be checked. The Readings on the BathyCorrometer® should be 0.000 with the checker switched off and -1.900V with the checker on.

Providing the readings are correct, the silver/silver chloride screw-in half cell should be checked by using K-SAT Reference Cells in a standard saltwater solution. To confirm the readings, three cells should be used, and the sea water corrosion test mixture should be made up to a 3% solution.

KIT COMPRISES

  • CalChecker Pro’
  • 3 x screw-on K-SAT reference electrode cells
  • Sea water corrosion test mixture
  • Full instructions for ‘in-house’ verification
FEATURES
  • Easy to use
  • All kit parts can be replaced individually
  • Full instructions included
CALIBRATION KIT FOR THE BATHYCORROMETER® PRO’
CalChecker Pro'
Power supply9 volt battery (PP3)
Battery typealkaline MN1604
Output voltage:1.990 Volts
Accuracy+/- 0.01%
Temperature coeff30ppm/°C
Temperature range0-30°C
On indicatorgreen LED
Low battery indicatorred LED
Connection5 pin plug & probe clip
K-SAT Reference Cell
Electrical connectionscrew fit
Output+196mV @ 25°C vs SHE
Accuracy±10mV @ 25°C vs SHE
Temperature coeff-0.64mV per/°C
Temperature range0 - 40 °C
Working lifeup to 1 year
Dimensions155mm long x 25mm dia.
Packed weight (calibration kit)1.9Kg
Dimensions (packed)44cm x 38cm x 14cm
Note: Due to ongoing technical developments, all stated information is typical and is subject to change without notice or obligation.
DESCRIPTIONPART NUMBERS
Calibration kit for the BathyCorrometer® Pro'BC-6004-0031