NDT
Home » NDT » Cathodic Protection » Reference Cells » Silver / Silver Chloride screw in half cell
NDT
Cathodic Protection - Buckleys

Reference Cells
Silver / Silver Chloride screw in half cell
The specially designed screw-in Silver/Silver Chloride Half Cell is for use in the Buckleys BathyCorrometers® and UCP1A and UCP1B underwater probes.
The Half Cell can be easily replaced in these units as it has a screw-in fitting. The water-tight seal is made by the use of an ‘O’ ring. The electrical connection to either a BathyCorrometer® or a UCP probe is made by a silver plated 3mm plug.
The electrode is housed in an acetate body. Holes in the body allow the easy flow of water, thereby removing any debris that might contaminate the electrode.
Providing the storage instructions are followed, the Half Cell will give a service life of up to two years.
FEATURES
- Easy to fit – screw-in
- Inert body casing: PVC
- Suitable for use in BathyCorrometers, UCP1A and UCP1B probes
- Long service life
SPECIFICATIONS
SILVER/SILVER CHLORIDE - AG/AGCL - SCREW-IN HALF-CELL | ||
---|---|---|
Screw thread | 1/2” UNF | |
‘O’ Ring Size | BS 111 | |
Electrical connection: | 3mm plug | |
Output | ≈ +250mV VS SHE | |
Temperature coeff | -0.6mV per°C | |
Temperature range | 0 - 30 °C | |
Working life | 1 to 2 years | |
Depth of operation | 700m+ | |
Weight (cell) | 5g | |
Dimensions (cell) | 46mm x 25mm | |
Packed weight | 0.3Kg | |
Dimensions (packed) | 26cm x 14cm x 30cm | |
Note: Due to ongoing technical developments, all stated information is typical and is subject to change without notice or obligation. |
REFERENCES
DESCRIPTION | PART NUMBERS | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Saturated Glass Reference CSilver/silver chloride - Ag/AgCl - screw-in half-cellell | BC-6004-0051 |