The latest screw-in K-SAT Reference Cell is an improved version of the original K-Series reference cell. It offers greater stability and a longer service life.
This K-SAT reference cell is used to verify the potential of the Silver/Silver Chloride/ Seawater (Ag/AgCl/seawater) half-cell in a BathyCorrometer®, UCP1A or UCP1B underwater probe.
It has been specifically designed to be used on the BathyCorrometer®. This is achieved by removing the stainless-steel probe tip and screwing on the K-SAT reference cell.
The potential of the internal Ag/AgCl/seawater reference cell can then be checked. To be confident in the results, ideally a set of three, different, K-SAT Cells should be used.
The cells can also be used for checking the UCP1A or UCP1B probes but an adaptor lead (6004-0018) and a high impedance voltmeter (greater than 10 M Ohm) would also be required.
The electrode is housed in a high resistance PVC body. The reference electrode is supplied with full operating instructions and will give a service life of up to 1 year if correctly maintained and used.
FEATURES
- Robust and easy to use
- Suitable for use with BathyCorrometers®, UCP1A and UCP1B probes
- Environmentally friendly vs calomel electrodes
- Inert body casing: PVC
- Long service life
- RoHS compliant
SPECIFICATIONS
K-SAT REFERENCE CELL | ||
---|---|---|
Electrical connection | screw fit | |
Output | +196mV @ 25°C vs SHE | |
Accuracy | ±10mV @ 25°C vs SHE | |
Temperature coeff | -0.64mV per/°C | |
Temperature range | 0 - 40 °C | |
Working life | up to 1 year | |
Weight (cell) | 70g | |
Dimensions (cell) | 155mm long x 25mm diam. | |
Packed weight | 0.3Kg | |
Dimensions (packed) | 26cm x 14cm x 30cm | |
Note: Due to ongoing technical developments, all stated information is typical and is subject to change without notice or obligation. |
REFERENCES
DESCRIPTION | PART NUMBERS | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Plastic-bodied K-SAT reference electrode | BC-6004-0111 |