NDT

NDT

Cathodic Protection - Buckleys

Buckleys
Reference Cells

Saturated Glass Reference Cell

The laboratory type Saturated Glass Reference Cell is an environmentally friendly & easily-maintained replacement for calomel cells and may be used to check and verify the accuracy of K-cells and installed Half Cells.

It has been designed to be connected to a separate high impedance voltmeter (greater than 10 meg Ohm) via a one metre lead.
The electrode is housed in a high resistance glass body and comes with a salt bridge solution for topping up.
The reference electrode will give a service life of several years if used in laboratory conditions and stored correctly.

FEATURES
  • Long cable length (1 metre)
  • Glass body casing
  • Environmentally friendly vs calomel electrodes
  • Refillable
  • Long service life
  • No specialist disposal required post lifetime
  • Supplied with fitted 4mm plug
SATURATED GLASS REFERENCE CELL
Electrical connection1 metre lead with 4mm plug
Output+196mV @ 25°C vs Standard Hydrogen Electrode (SHE)
Accuracy+/- 10mV @25°C vs SHE
Temperature coeff-0.64mV per °C
Temperature range0 - 40 °C
Cable length1m
Size155mm long x 25mm diameter
Weight (cell)250g
Packed weight0.5Kg
Dimensions (packed)13cm x 7cm x 27cm
Refill Solution 6004-0133 is available from Buckleys
Note: Due to ongoing technical developments, all stated information is typical and is subject to change without notice or obligation.
DESCRIPTIONPART NUMBERS
Saturated Glass Reference CellBC-6004-0132