NDT
Home » NDT » Cathodic Protection » Reference Cells » Saturated Glass Reference Cell
NDT
Cathodic Protection - Buckleys

Reference Cells
Saturated Glass Reference Cell
The laboratory type Saturated Glass Reference Cell is an environmentally friendly & easily-maintained replacement for calomel cells and may be used to check and verify the accuracy of K-cells and installed Half Cells.
It has been designed to be connected to a separate high impedance voltmeter (greater than 10 meg Ohm) via a one metre lead.
The electrode is housed in a high resistance glass body and comes with a salt bridge solution for topping up.
The reference electrode will give a service life of several years if used in laboratory conditions and stored correctly.
FEATURES
- Long cable length (1 metre)
- Glass body casing
- Environmentally friendly vs calomel electrodes
- Refillable
- Long service life
- No specialist disposal required post lifetime
- Supplied with fitted 4mm plug
SPECIFICATIONS
SATURATED GLASS REFERENCE CELL | ||
---|---|---|
Electrical connection | 1 metre lead with 4mm plug | |
Output | +196mV @ 25°C vs Standard Hydrogen Electrode (SHE) | |
Accuracy | +/- 10mV @25°C vs SHE | |
Temperature coeff | -0.64mV per °C | |
Temperature range | 0 - 40 °C | |
Cable length | 1m | |
Size | 155mm long x 25mm diameter | |
Weight (cell) | 250g | |
Packed weight | 0.5Kg | |
Dimensions (packed) | 13cm x 7cm x 27cm | |
Refill Solution 6004-0133 is available from Buckleys | ||
Note: Due to ongoing technical developments, all stated information is typical and is subject to change without notice or obligation. |
REFERENCES
DESCRIPTION | PART NUMBERS | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Saturated Glass Reference Cell | BC-6004-0132 |