NDT

Ultrasonic Thickness Gauges -Cygnus

Cygnus
Surface Thickness Gauges

Cygnus 6+ PRO

Ultrasonic Thickness Gauge

The Cygnus 6+ PRO thickness gauge boasts a full range of useful features forprofessional users, including A-scan, B-scan and comprehensive data logging. Used with Cygnus High Temperature probe, the Cygnus 6+ PRO can measure remaining wall thickness of high-temperature, in-service assets without shutdown or isolation.

Comprehensive Data Logging

  • Linear, 2D grid and template based logging
  • 16 grid patterns available
  • Add radial points to any measurement to further investigate immediately an area of interest or heavy corrosion
  • Eight user-defined text comments to attach to any measurement point
  • Auto-log feature
  • Saves measurements and A-scans
  • Records stored on an SD card
  • CygLink software used to transfer and manage data
FEATURES
  • Multiple-Echo mode for accurate, through-coat measurements as specified by Classification Societies
  • Echo-Echo and Single-Echo modes for heavily corroded metals with a thin or no coating
  • Temperature Compensation feature for measurement on hot materials
  • Deep Coat function ignores coatings up to 20mm thick
  • Manual and automatic gain control
  • Min/max measurement limit functions with visual and vibrate alert
  • Uses single and twin crystal probes
  • Freeze function
  • One and two point calibration
  • Bluetooth for data transfer
  • Large front LCD display and end-mounted rotatable LCD display with grayscale setting for bright sunlight
  • Safe operation in explosive atmospheres: Class 1, Division 2, Group D locations only, as defined in NFPA 70, Article 500
  • Water and dust tight IP67 housing
  • Shock and impact proof to US MIL STD 810G
CYGNUS 6+ PRO
Measuring ModesMultiple-Echo using 3 echoes to ignore coatings up to 20 mm thick
Echo-Echo using 2 echoes to ignore coatings up to 1mm thick
Single-Echo using 1 echo
MaterialsVelocities from 1,000 - 9,000 m/s (0.0390 - 0.3543 in/us)
Accuracy±0.05 mm (±0.002”) - in Multiple-Echo measurement mode, when calibrated and measuring the same material as calibrated on.
±0.1 mm (±0.004”) or 0.1% of thickness measurement whichever is the greatest - in Single-Echo & Echo-Echo measurement modes, when calibrated and measuring the same material as calibrated on.
ResolutionMultiple-Echo mode - 0.1 mm (0.005”) or 0.05 mm (0.002”)
Single-Echo and Echo-Echo modes - 0.1 mm (0.005”) or 0.01 mm (0.001”)
Probe OptionsSingle Crystal probes, Twin Crystal probes and High Temp probe
Measurement Range in Steel0.8 – 250mm (0.031 in. – 10 in.) depending on selected probe and configuration, material and temperature
Connector2 x Lemo 00
Power3 x AA / R6 batteries
Battery LifeApprox. 10 hours continuous measurement
ElectronicsDual channel pulser
DisplayFront LCD 2.4” QVGA 47 mm (W) x 37 mm (H); End-mounted LCD 25.58mm (W) x 6.38 (H)
Size84mm x 130mm x 35mm (W x H x D) (3.3” x 5.1” x 1.4”)
Weight300g (10.5 oz.) (inc. batteries)
Operating Temp.-10°C to 50°C (14°F - 122°F)
Data Logging5000 measurements and A-scans per record. Max number records: 100 (soft limit)
Computer SoftwareCygLink allows remote logging and viewing of A-scan graphs
Survey and report generation to PDF file
Graphic analysis of data and statistical calculations
Environmental RatingIP67
Safe operation in Explosive Atmospheres: Class I, Division 2, Group D Locations only, as
defined in the National Fire Protection Association Code (NFPA 70), Article 500.
Tested using MIL-STD-810G, Method 511.5, Procedure I
MIL STD 810G Method 501.6 (high temp +55°C (131°F))
MIL STD 810G Method 502.6 (low temp -20°C (-4°F))
MIL STD 810G Method 507.6 (humidity 95%)
MIL STD 810G Method 512.6 (immersion 1 metre for 30 mins)
Shock and ImpactMIL STD 810G Method 514.7 (vibration)
MIL STD 810G Method 516.7 (shock 20g)
MIL STD 810G Method 516.7 (transit drop 1.22 m)
StandardsDesigned for EN 15317
ComplianceCE, UKCA, RoHS
Warranty3 years on gauge and 6 months on probe
DESCRIPTIONPART NUMBERS
CYGNUS 6+ PRO
Cygnus 6+ PRO Mk5 UTG Kit, without ProbeCY-050-6500/5
Probe S2C Single 2.25MHz 13mm with BNC connectorCY-004-9500
Probe S3C Single 3.5MHz 13mm with BNC connectorCY-004-9504
Probe S5C Single 5MHz 13mm with BNC connectorCY-004-9508
Probe Lead Twin Lemo 00 to BNC 1.35m (4'6")CY-004-0410
Probe S5A Single 5MHz 6mm with Single Lemo 00 connectorCY-004-9507
Probe Lead Twin Lemo 00 to Single Lemo 00 1.4m (4'6")CY-004-0412
Probe T2C Twin 2MHz 17/12mm with Twin Lemo 00 ConnectorCY-004-9550
Probe T5B Twin 5MHz 13/8mm with Twin Lemo 00CY-004-9558
Probe Lead Twin Lemo 00 to Twin Lemo 00 1.35m (4'6")CY-004-0411
Probe T5B-CSW 5MHz 13/8mm Side Exit Cable to Twin Lemo00CY-004-9590
Probe T5A Twin 5MHz 9.5/6.5mm Side Exit Cable to Twin Lemo 00CY-004-9560
Probe T7A-CSWB Twin 7.5MHz 6.5/4.5mm Side Exit Cable to Twin Lemo00CY-004-9591
PROBE T5B-MAUH 5MHz Twin elementCY-004-9561
Probe Lead Twin Lemo 00 to Microdot for T5B-MAUHCY-004-0418
Probe Lead Twin Lemo 00 to Microdot S/S BraidCY-004-0417
COUPLANT High Temperature (-45C° to 455°C) 4oz/118 mlCY-001-3735
Test Block Steel 4 Step Metric 2.5 - 20mm 2.5/5/+A2610/20CY-001-4858
Test Block Steel 4 Step Imperial 0.1 - 0.75 inchCY-001-4859
Marinised Probe S2C 2.25MHz 13mmCY-002-9387
Marinised cable for use underwater priced per metreCY-001-0434
Twin Lemo 00 to Single Lemo 1 adapter for C2+/C4+/C6+Mk5 UTGCY-050-0106
Mini USB cable for data transferCY-050-0120
Bluetooth Adapter V4.0 USB BelkinCY-050-0125
Neck Strap with fixings for C2 / 2+ / 4 / 4+ / 6+ Mk5 UTGCY-050-0115
Hand Strap with fixing for C2 / 2+ / 4 / 4+ / 6+ Mk5 UTGCY-050-0110
Belt Clip with fixing for C2 / 2+ / 4 / 4+ / 6+ Mk5 UTGCY-050-0100
Peli Carry Case for Cygnus 6+ Mk5 Gauge KitCY-050-6511/5