NDT
NDT - Cygnus

FMD
Cygnus FMD System
Ultrasonic Flooded Member Detector
With over three decades of designing ultrasonic equipment for the offshore and underwater environment, Cygnus fully understands the requirements of the subsea inspection industry. This entirely new Flooded Member Detector (FMD) combines intelligent, advanced software and electronics with a truly simple to use interface.
The FMD system is both diver or ROV deployable. Being of a compact design the probe is able to get into hard to reach areas (e.g. K nodes) where other inspection methods cannot. A range of versatile options to suit working depths and varying requirements are available.
FEATURES
- VERSATILE: The FMD system is both diver or ROV deployable.
- COST EFFECTIVE: The Cygnus FMD System is owner operated and extremely easy to learn and understand.
- EASY TO USE: The Cygnus FMD has an innovative probe handling solution which self aligns, ensuring correct contact with the member, even when approached from an angle.
- RUGGED: Available in high grade acetal or stainless steel for the harshest environments.
- RELIABLE: Cygnus is an ultrasonic specialist. Years of industry experience and design expertise combine to make this system an extremely advanced, effective and reliable Ultrasonic FMD System available.
- FMD REPORTING SOFTWARE:
- Used to perform system tests
- Displays test results
- Displays A-Scans for verification
- Indicator shows RED if flooded, GREEN if dry
- Logs results for offline analysis
- Reports can be generated and exported to PDF and Excel
SPECIFICATIONS
CYGNUS FMD SYSTEM | ||
---|---|---|
POWER SUPPLY REQUIREMENTS (Generic) | ||
Power Supply Input to Electronics Bottle | 12-24V supply input @ 60mA (average current) @ 200mA (maximum current) | |
POWER SUPPLY REQUIREMENTS FOR POWER SUPPLY AND COMMA UNIT (DIVER) | ||
Mains supply | 110AC or 230VAC | |
CONNECTIONS | ||
Probe connector | CRE PL-A-09-M. Mates with Bulkhead CRE BR-A-09-F Type 19 | |
Power/Comms connector | MCBH4F | |
External Power/Comms connector | MCBH6M | |
GENERAL ATTRIBUTES | ||
Operating Temperature Range | -10°C to +50°C (14°F to 122°F) | |
Storage Temperature Range | -10°C to +35°C (14°F to 95°F) | |
Measurement Ranges | 200mm(0.2m) to 2500mm(2.5m), 0.66ft to 6.56ft | |
Measurement Resolution | 1mm | |
TRANSMITTER | ||
Pulser Voltage | 100V to 400V (adjustable) | |
Pulse Width | 850ns (adjustable) | |
Damping | 470 Ohm | |
RECEIVER | ||
Useable Gain range | 0dB to 70dB (adjustable) | |
PROBE | ||
Centre Frequency | 0.5MHz | |
Technology | Piezo-composite | |
PRESSURE RATING | ||
Electronics Bottle | Tested to 400m | |
Probe Assembly | Tested to 400m | |
OTHER | ||
Compliance | CE, UKCA, RoHS. Declarations of Conformity supplied with kit. | |
DRY WEIGHTS | ||
Electronics bottle (stainless steel) | 4.87kg | |
Electronics bottle (acetal) | 0.9kg | |
Probe Holder (stainless steel) | 4.5kg max. | |
Probe Holder (acetal) | 1.95kg max. |
REFERENCES
DESCRIPTION | PART NUMBERS | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
FMD-M1 5m CRE Probe / Software / Peli case | CY-110-0341 | |||||||||||
FMD-M1 Subsea Electronics Module CRE - Stainless Steel | CY-110-0230 | |||||||||||
FMD-M1 Subsea Electronics Module CRE - Acetal | CY-110-0231 | |||||||||||
FMD-M1 Probe Handler - Acetal | CY-110-0050 | |||||||||||
FMD-M1 Probe Handler - Stainless Steel | CY-110-0051 | |||||||||||
3/4" T-Bar Manipulator Handle | CY-001-8314 | |||||||||||
1/2" T-Bar Manipulator Handle | CY-001-8315 | |||||||||||
Fishtail Manipulator Handle | CY-001-8316 | |||||||||||
FMD-M1 set of ROV components | CY-110-0321 | |||||||||||
FMD-M1 set of diver components | CY-110-0322 | |||||||||||
FMD-M1 Electronics Module Cable Support Cage | CY-110-0213 | |||||||||||
ROV & FMD-M1 Electronics Module Cable Support Cage (Long for CRE) | CY-110-0216 | |||||||||||
FMD-M1 System Test Piece | CY-110-0204 | |||||||||||
FMD-M1 System Test Piece (DRAWING ONLY) | CY-110-0206 | |||||||||||
FMD-M1 120m Umbilical Cable and Reel | CY-110-0211 | |||||||||||
FMD-M1 Probe 0.5MHz, 5m Cable and Connector | CY-110-0201 | |||||||||||
FMD-M1 Probe 0.5MHz, 5m Cable and CRE Connector | CY-110-0233 | |||||||||||
FMD-M1 Probe 0.5MHz, 2m Cable and Connector | CY-110-0202 | |||||||||||
FMD-M1 Probe 0.5MHz, 2.5m Cable and CRE Connector | CY-110-0232 | |||||||||||
FMD-M1 Surface PSU and Comms Connection Unit | CY-110-0205 | |||||||||||
FMD-M1 Software and Manual on USB Flash Drive | CY-110-0316 | |||||||||||
FMD-M1 Pelican Transit Case | CY-110-0304 | |||||||||||
FMD-M1 USB 2.0 Cable Male USB A to Male USB B 1.8m | CY-110-0303 | |||||||||||
ROV & FMD-M1 RS232 to USB cable assembly 1m | CY-110-0324 | |||||||||||
Patch cable 0.6m for FMD & 2000M/4000M ROV UTG | CY-001-0451 | |||||||||||
FMD-M1 3m test cable | CY-110-0315 | |||||||||||
ROV & FMD-M1 Dual Test Lead RS485 & RS232 to 2 x 9WD | CY-110-0323 | |||||||||||
Isolated Data Converter (RS422/RS485 to USB) | CY-001-8305 | |||||||||||
FMD-M1 Subconn Micro Circular Adaptor | CY-110-0302 | |||||||||||
ROV & FMD-M1 SPARES - Subsea Electronics Module O-ring kit | CY-110-0317 | |||||||||||
FMD-M1 SPARES - Subsea Electronics Module O-ring kit (acetal) | CY-110-0318 | |||||||||||
FMD-M1 Probe Knurled Ring Nut (S/S) | CY-110-0300 | |||||||||||
FMD-M1 Probe Handler Probe Body Spring | CY-110-0301 |