Air Breathing Compressors

High Pressure Compressors

Notus Series

Why Notus

NOTUS, Paramina’s new ‘’Force’’ in high pressure piston compressor series. Heavy duty design for continuous operation during the day, easy-to-move, 3-staged, oil lubricated and air cooled, offering pure breathing air according to EN 12021. NOTUS is suitable for indoor or open area installations, mobile rescue squads, fire trucks, diving boats & paintball teams. Its robust construction makes it suitable for several industrial applications as well.

Notus Classic models provide fully automated versions as an “option
TECHNICAL DATA
  • Oil capacity: 1.2 lit special synthetic compressor oil.
  • Permissible ambient temperature: +5 oC to +45 oC.
DESIGN SPECIFICATIONS NOTUS HP SERIESN10-EM OpenN10-ET OpenN10-ET ClassicN10-ET Open
Micronic Air Inlet Filter●●●●
Condensate Separator after 2nd Stage●●●●
Large Stainless Steel Intercoolers – Aftercooler in all stages●●●●
Combined BA Filter including Coalescing Pre-filter (0.5mg/m3 oil residual) and 2 x BA cartridges (AC/MS + HP option), with the supply of absolutely clean air exceeding by far the requirements of EN 12021●●●●
Safety Bleed valve in case of BA Cartridge absence◆◆◆◆
Pressure maintaining & non-return valve for extended filtration●●●●
Start/Stop switch●●●■
Motor thermal overload protection●●●■
Manual Condensate Drains●●●●
Kevlar filling hose (1.2m) with stainless steel fittings and DIN/INT’L connector●●●●
Handles for easy lifting●●■●
Safety Valves in all stages●●●●
Final Stage manometer●●●●
Automatic belt tensioning system●●●●
Electric hourmeter●●●■
Vibration hourmeter / service timer (Running hours, BA filter / oil service hours)◆◆◆●
Automatic stop system◆◆◆◆
Automatic start system◆◆◆■
Automatic condensate drains with manual backups + Condensate collecting tank.◆◆◆■
Dual pressure filling facility, allowing 225/330bar alternative filling◆◆◆◆
Star/Delta starter system■■◆■
Low oil level monitoring / alarm / shutdown■■◆■
High temperature monitoring / alarm / shutdown■■◆■
24VAC secondary voltage providing safety during routine operation■■◆■
Emergency Stop button■■●■
Main Switch■■●■
Remote start/stop■■◆■
Condensate separator after 3rd (final) stage◆◆◆◆
Interstage manometers●●●●
1.5m air inlet hose with particle strainer◆◆◆●
Special voltage/frequency 3x230V/60Hz * 460-480V/60Hz■■◆■
● STANDARD      I        ◆ OPTIONAL      I       ■ NOT APPLICABLE
  • Automatic Stop
  • Automatic Start
  • Automatic condensate Drains
  • Extra Filling Hose
  • Dual pressure filling facility, allowing 225/330 bar filling
  • Condensate collector vessel, external
  • Interstage manometers (std on Classic version)
  • 1,5m air inlet hose with particle strainer
  • Start/Delta starter (only for Classic version)
  • Low Oil level alarm (only for Classic version)
  • High Temperature alarm (only for Classic version)
  • 24VAC secondary voltage providing safety during routine operation (only for Classic version)
  • Emergency stop button (only for Classic version)
  • Main Switch (only for Classic version)
  • Remote start/stop (only for Classic version)